BioSAFE Engineering - A Clean Energy Company

1000 lb/hr

1000 lb/hr

1,000 lb per hour medical waste treatment unit

Throughput Capacity 1000 lb (455 kg) per hour
Operating Temperature Waste in auger chamber: 205-212°F (96-100°C)
Steam in auger chamber jacket: 220-240°F (104-115°C)
Construction Material Stainless steel (optional painted steel)
Dumper Hydraulic
Available Configuration Floor or dock mounted door
Safety
  • Safety switches on all access panels
  • Door release inside cart dumper
  • Siemens PLC monitored alarm matrix
  • Spore testing made easy
  • Operator and maintenance training program
Electrical Controls Shredder: NEMA 4 cabinet
Main: NEMA 4 with Siemens PLC and touchscreen
HEPA Filter Min. operational efficiency of 99.97@0.3 microns
Time in Auger Chamber ≥ 60 minutes
Maximum Cart Size 220 gallons (800 liters) x 2 carts/lift
Recommended Utilities Sewer: 4″ flush trapped floor drain to accept 4″ ID connection
Ventilation:
4″ to outside above roof (steam) (piping by others)
8″ to outside above roof (HEPA) (piping by others)
Make-Up Air: 1400 CFM (If installed indoors)
Steam: 400-500 lb/hr minimum flow regulated to 13-14 psig max and 1″ minimum diameter pressure relief valve set @ 14 psig max
Electric: Shredder: 480 VAC, 3 phase plus ground, 150 amp, 60 Hz
Communications: Ethernet cat5 preferred or standard 4 wire analog with call access.
(All utilities within 10 feet of unit)
Options
  • Stainless steel enclosures or painted steel construction
  • Floor mounted or dock mounted door
  • Door entry location is flexible
  • Hood over dumper
  • Waste carts/wheelie bins
  • Service contract
  • Additional training services