BioSAFE Engineering - A Clean Energy Company

300 lb/hr

300 lb/hr

300 lb per hour medical waste treatment unit

Throughput Capacity 300 lb (136 kg) per hour  
Operating Temperature Waste in auger chamber: 205-212°F (96-100°C)
Steam in auger chamber jacket: 220-240°F (104-115°C)
 
Construction Material Stainless steel (optional painted steel)  
Dumper Electric  
Available Configuration Floor or dock mounted door  
Safety
  • Safety switches on all access panels
  • Locking entry door with cutout switch
  • Lighted E-STOP and door release inside cart dumper
  • Siemens PLC monitored alarm matrix
  • Spore testing made easy
  • Operator and maintenance training program
 
Electrical Enclosures Shredder: NEMA 4 painted mild steel.
Main: NEMA 4 with Siemens PLC and touchscreen
 
HEPA Filter Min. operational efficiency of 99.97@0.3 microns  
Machine Footprint Dependent on configuration. Contact us for assistance.  
Time in Auger Chamber ≥ 60 Minutes  
Standard Cart Size 96 gallons (365 liters)  
Recommended Utilities Sewer: 4″ trapped sanitary drain connection
Ventilation: 4″ to outside above roof (2 vents) schedule 80 cpvc.
Make-Up Air: 1000 CFM (If installed indoors).
Steam: 200-300 lb/hr regulated to 15 psig max and pressure relief valve set @ 15 psig max
Electric: Shredder: 480 VAC, 3 phase plus ground, 70 amp, 60 Hz, fused disconnect main: 480 VAC, 3 phase plus ground, 30 amp, 60 Hz
Communications: Ethernet cat5 preferred or standard 4 wire analog with call access.
(All utilities within 10 feet of unit)
 
Options
  • Stainless steel or painted mild steel construction
  • Floor mounted or dock mounted door
  • Waste carts/wheelie bins
  • Service contract
  • Additional training services